The cleanroom AHU realizes the functions of refrigeration, heating, dehumidifying, heating, humidification, purification and sterilization through a variety of heat and humidity treatment schemes and air purification treatment, so as to achieve precise control of the indoor environment temperature, humidity, and cleanliness.


  • Core Advantages
  • Core Technology
  • Technical Parameters
  • Application Scenarios
  • Optional Systems
  • 1. Cleanroom AHU

    The air volume of the combined air handling unit(AHU) ranges from 3500m³/h to 200,000m³/h for users to choose and combine freely. It is mainly suitable for the air purification system of various clean workshops. Such as industrial electronics factory, precision machinery manufacturing factory, textile workshop, automobile spraying workshop, GMP pharmaceutical factory, cosmetics, food factory, pure water workshop, hospital operation department, ICU and other occasions.

    According to the structure type, it can be divided into horizontal, vertical and ceiling type; according to the characteristics of use, it can be divided into general unit, fresh air unit, purification unit and special unit (such as roof unit, subway unit and computer room special unit, etc. ); it can also be classified according to specifications, the basic specifications of the unit can be expressed by the rated air volume.

    The basic principle of setting the functional section of the purification unit is determined according to the production process or cleanroom requirements; the combination and selection of the functional section of the purification unit should be closely integrated with the design of the air-conditioning room, and the microbial contamination points in the purification unit must be controlled. Because the structure, temperature and humidity are more suitable for the growth of bacteria and other microorganisms, the cabinet, filter, muffler, humidifier, etc. of the purification unit have become potential microbial contamination place, which must be controlled. If the unit box is free from damage and corrosion, disinfection resistance, heat preservation and sealing performance, we can use antibacterial materials that have been widely used in refrigerators; filter performance indicators meet the requirements; mufflers, humidifiers, etc., do not retain materials. The functional segments of the air conditioning unit are as follows:

    • New return air mixing section; the new return air opening position can be set at the end, top or left and right sides according to the design requirements, and specific opening positions should be provided for special requirements. A regulating valve can be installed on the new air return port. The actuator has three types of manual, electric and pneumatic, which can be selected by the user.
    • The filter section has two kinds of primary and medium-efficiency filtration. It is equipped with a diamond bag type, a four-peak bag type, and an automatic winding type. The filter material is made of high-quality polyester non-woven fabric, and the filter is quickly assembled and disassembled, gland display and alarm device
    • The new exhaust section (also known as the flat air-distribution mixing section) is equipped with a primary air return valve in the box. The top of the box before and after the valve is equipped with an exhaust outlet and a new air outlet, and is equipped with a regulating valve. Its function is: When there is a return fan, supply the air conditioner to discharge part of the return air, so that the fresh air and the primary return air are mixed according to the required ratio; when the direct current system is adopted in the transition season, the primary return air valve should be closed, and the exhaust valve and fresh air valve should be fully opened.
    • The energy recovery section is used for cross-air mixing and exhaust air energy recovery in the dual fan system. This section of the box is equipped with a primary air return valve, and the top is an energy recovery device. It uses the cold (heat) of the exhaust air to indirectly cool (heat) the fresh air. The fresh air passes through the plate energy recovery device to recover about 60% of the sensible heat energy of the exhaust air. At the same time, the exhaust air and the fresh air are not direct contact, which is especially suitable for energy recovery of the DC air-conditioning system that eliminates harmful indoor gases. When used as a DC system, the return air valve should be closed once. Places with highly toxic gases should have a separate exhaust system.
    • Intermediate section (maintenance section) This section is used for the connection of the transition section and the internal maintenance lighting of the unit. Before the filtering section, there must be an intermediate section before and after the surface cooling section, heating section, and muffler section.
    • The middle section of the second air return pipe of the secondary air return section, the top can be equipped with an adjustable valve, and it is equipped with manual, electric or pneumatic adjustment mechanisms, which can be selected by the user. This section can also be combined in the blower section.
    • The surface cooler of the surface cold section adopts the structure of copper pipes and aluminum foil. The aluminum foil is in the form of flanging and corrugated edges. The large elbow heat exchanger reduces the welding elbow by 60%, which increases the heat exchange power. The advanced mechanical expansion tube form ensures the contact performance of the heat exchanger. The heat exchanger is divided into two types: fixed type and rotary type. Users can choose one according to their needs. The heat medium is steam or hot water.
20 +

Years rich Industry Experience

3 +

Production Bases

60 +

Successful Projects in 60 Countries

300 +

Loyal Clientele




Trusted Worldwide

Invited to the Embassy of the United Republic of Tanzania in Guangzhou to discuss projects

Trusted Worldwide

Tanzanian Vice President Visits Marya Pharmaceutical EPC Project

Trusted Worldwide

NBA (Zimbabwe National Biotechnology Authority) conducts FAT at MARYA’s Factory

Trusted Worldwide

NOVO NORDISK client Visit

Trusted Worldwide

Clients visit the factory's liquid preparation system

Trusted Worldwide

Argentine client visits for FAT in MARYA



Marya

INTERESTED IN MARYA?

Get In Touch With Us.

We Will Be Happy To Discuss Our Solutions And Services With You.

Contact Now

Services


img

Are you manufacturer or trader? Where are your factory located?


img

We are manufacturer. Our factory is located in Changsha and Suzhou.

img

What certificate do you have?


img

We have CE, ISO, ROHS, SGS etc.

img

What documents will you provide?


img

Usually we will provide DQ, IQ, PQ, OQ, FAT, SAT, operation manual, maintenance instruction,layout drawing.etc.

img

What is the production lead time?


img

Standard 25-60 days after deposit received and technical data confirmed, we can make special arrangement for better shipment if needed;
Standard 60-150 days after deposit received and technical data confirmed based on different machines, we can make special arrangement for better shipment if needed.

img

How long is your warranty? Can we extend?


img

12 months after installation and commissioning or 18 moths from the day that the equipment arrived on site. Prevail in the first arrival date.
Warranty can be extended with extra charge.

img

Have you done similar projects overseas?


img

Marya’s business map covers more than 60 countries and regions around the world, such as the United States, Russia, Bulgaria, Britain, Portugal, Poland, Switzerland, ltaly, New Zealand, Malta, Moldova, Malaysia, Uzbekistan, lran, Egypt, Saudi Arabia, UAE, Ecuador, Dominica, Panama, Uruguay, Argentina, Tanzania, Zimbabwe, Ethiopia, Indonesia, Bangladesh, and others, and we gained good reputation.

Key words:

cleanroom

cleanroom hvac

Cleanroom Air Handling Unit

cleanroom AHU

Contact MARYA Engineers to Claim Your Free GMP compliant Sterile Pharmaceutical Production Line Solution

CONTACT INFO

NO211, North Fute Road, Pudong area, Shanghai, China, 200131

Please Leave Your Contact Information

%{tishi_zhanwei}%